Pitot Heat Failure; Starter Engaged - Piper ARCHER III Pilot Operating Handbook

Hide thumbs Also See for ARCHER III:
Table of Contents

Advertisement

SECTION 3
EJ\1ERGENCY PROCEDURES
3.Sf

Pitot Heat Failure

Indication: Master Caution, Double Chime,
PITOT HEAT Switch .......................................................................... OFF
PITOT HEAT Circuit Breaker (Row 2, Col. 2) .............................. RESET
PITOT HEAT Switch ............................................................................ ON
If Pitot Heat still inoperative:
Exit and A void Instrument Meteorological Conditions.
3.Sg Starter Engaged
Indication: Master Warning, Triple Chime,
If on the ground:
THROITLE ................................................................................. REDUCE
ENG ST ART Circuit Breaker (Row I, Col. I 0) ............................... PULL
ENGINE ................................................................................ SHUTDOWN
If in flight:
THROTTLE ................................................................................. REDUCE
ENG ST ART Circuit Breaker (Row I, Col. I 0) ............................... PULL
Land as soon as possible.
REPORT: VB-2749
3-38
Pitot Heat Failure

Starter Engaged

PA-28-181, ARCHER ill
PITOT
HEAT
FAIL
STARTENGD
ISSUED: December 22, 2017

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pa-28-181