Technical data

Table 1 General

Measurement range
Accuracy
W601xxxxx
Temperature effect on zero
Temperature effect on span
Resolution
Gas type dependence
Mass
*
Non linearity, hysteresis, repeatability in the calibrated range at 25 °C ambient
operating temperature without temperature effects after 2 hours of operation.

Table 2 Output signal

Output signal analogue (measurement signal)
Voltage range
Measurement range
Relationship voltage-pressure
Output impedance
Loaded impedance
Response time

Table 3 Gauge identification

Gauge identification
WARNING: HIGH VOLTAGE
Risk of electrical shock. The gauge can only be connected to power supplies, instruments
or control devices that comply with the requirements of a grounded Protective Extra-Low
Voltage (PELV) and Limited Power Source (LPS), Class 2. The connection to the gauge has
to be fused.
*
Edwards controllers meet this requirement.

Table 4 Electrical

Supply voltage
at the gauge
ripple
Current consumption
Power consumption
Fuse required
W601100880_A - Technical data
*
*
*
1.0% of reading
0.02% F.S./°C
0.02% of reading/°C
0.05% F.S.
None
 g
-0.2 to +10.24 V
0 to +10 V
Linear
10  (short circuit proof)
> 10 k
100 ms
Resistance 18 k referenced to supply
common
+13 to +32 V d.c.
Class 2 / LPS
 V
pp
< 20 mA
0.3 W
1 AT (slow), automatic reset (Polyfuse)
Page 9