2.7.1 Starting of the heating module
2.7.2 Driving of the additional outlets
2.8 Keypad and display working
2.8.1 Selection of the mode :
Automatic modes: User selects the required automatic mode on the control panel, no need to select the diameter
CARBIDE 5800: optimised shrink grip & release of carbide and heavy metal tools in type 5800 holders
CARBIDE 5801: optimised shrink grip & release of carbide and heavy metal tools in type 5801 holders
CARBIDE 5603: optimised shrink grip & release of carbide and heavy metal tools in type 5603/5803 holders
CARBIDE 5600: optimised shrink grip & release of carbide and heavy metal tools in type 5600 holders
STEEL 5600: shrink grip & release of HSS and steel tools in type 5600 holders
STEEL 5800-5801-5603: shrink grip & release of HSS and steel tools in type 5800, 5801, 5603/5803 holders.
Programmable modes: User programms the suitable cycle, in one of the 50 files of modes PRG1 and PRG2, using the
control panel.
Mode PRG1: possibility to programm up to 25 customised heating cycles
Mode PRG2: possibility to programm up to 25 customised heating cycles
Seco Shrinkfit holders Code key
E= Monobloc holder
Back end taper type
Switch on the module by pressing key
Select the required mode on the control panel according to the Shrinkfit holder
front end type (see § 2.8.1) and press key
Device is ready for a shrink grip or release heating cycle.
Switch off the control panel by pressing key
The heating module is equipped with 2 additional outlets to drive the other modules (support
modules, cooling modules).
- X1 outlet is switched on by pressing key
- X2 outlet is switched on by pressing key
Note : Outlet X1 can only be activated if the control panel has been started.
E 9304 5603 10 120
Front end type
Tool fitting Ø size
21
and switched off by pressing key
and switched off by pressing key
Gauge length