- Once the inductor is unlocked, center it (for example, using a conical toolholder set
on the finned support); then rescrew the four screws.
- Set up the comparator back.
2.5 Connections
All Packs:
AC 3x400V (+/-10%) + PE/ 16 A/ 50-60Hz/ Differential breaker 30 mA. 3 meter
cable is supplied.
AC 1x230V + PE/5A/50-60Hz, cable with a DE/FR electrical plug is supplied
with support box. For connections see paragraph 3.2 and 4.2
Additional for Pack N°3 :
+ AC 1x230V + PE/5A/50-60Hz, cable with a DE/FR electrical plug is supplied
with refrigerated water cooling. For connections see paragraph 5.3
Air 3 to 6 bar/ pipe internal Ø 7 mm required (for heating system).
Type C circuit breaker.
Remark : Transformer for USA or Canadian voltages is available as an optional
accessory.
2.6 Starting
Switch on main interruptor of the heating module.
On the display the yellow LED will go on.
Display shows : POWER OFF.
19