3
2
1
Cooling mode
water cooling bells
finned cooling tubes
cooling cone
In order to access to the coding wheels, the right housing must be unmounted. This
housing is maintained by 4mm allen screws, both on the side and at the back of the
module.
Remove the 3 screws at the back of the module + the 3 bottom screws on the side of
the module. BEWARE: the upper screws are used to index the rotating plates. They
must not be unscrewed.
Move the right housing away to access the command card.
Program the coding wheels using a flat screwdriver:
(1)
- the right one
sets the hundreds figure,
(2)
- the central one
sets the tens figure,
- the left one
(3)
sets the units figure..
advised timing
minutes
seconds
2 min
120 s
4 min
240 s
8 min
480 s
Set the right side housing back. Plug the power and pneumatic supply wires back in.
29
units figure tens figure
0
2
0
4
0
8
hundreds
figure
1
2
4