Page 2
This warranty covers the material defects. Any defect that occurs due to mishandling that is not mentioned in this Operating instructions manual, or due to an improper maintenance, etc. is not covered. Seco’s sole liability is limited to repairing or replacing the product.
DELIVERY CONTENT Heating column Main plate (1 piece) (1 piece) Universal sliding Support ring Cooling cone support (1 piece) (1 piece) (1 piece) Standard heat Heat protective gloves focusing stopper (1 pair) (complete set of 5 pieces) Set of 2 fixing screws and 1 User instructions cable tie (1 piece)
1. INTRODUCTION 1.1. Shrinking principle The Shrinkfit holder’s inside diameter is designed to be slightly smaller than the shank diameter of the cutting tool (step 0). Using an heating system, the toolholder’s inside bore of the Shrinkfit holder is heated and expands. The tool shank can then be slipped easily into it (step 1).
2.2.2. Support ring Once set on the universal sliding support, the support ring allows a direct holder positioning. Available for all types of toolholders (SA30 to SA50, HSK25 to HSK100, Seco-Capto C3 to C8). Part N° ZFAR07xx 2.2.3. Air cooling cone Once set on the universal sliding support, the air cooling cone focuses the air stream against the holder front end for cooling.
2.2.6. Depth rulers for Shrinkfit depth setting A depth ruler is an economic alternative to the depth comparator, enabling easy setting of the stop rods on Packs Easyshrink 20 according to a required Shrinkfit depth. The distance between stop rod’s front ®...
2.4. Localisation of the device The Easyshrink device is a table device, to be localized in a dry and clean working place, on a stable and rigid surface. ® 2.5. Mounting A bag with two fixing screws and one cable tie is delivered on the main plate of the device. Make sure you save these parts that are required to mount the device.
Page 9
4) Plug the fans’ power supply wire in. ‘clic’ 5) Use the provided cable tie to fix the fans’ power supply wire on the main plate. 6) The main plate’s feet (on the back, left corner) can be set in height to warranty the stability of the device.
Tension in V PE → L1 PE → L2 PE → L3 L1 → L2 L1 → L3 L2 → L3 Note: A transformer for USA or Canadian voltages is available as an optional accessory. Please contact your Seco representative.
3. EASYSHRINK ® 15 DEVICE: GENERAL DESCRIPTION 3.1. Overview Keypad and display Main swith Inductor housing Storage rack for heat focusing main plates Storage rack for support rings Storage rack for tools Main plate Universal sliding Cooling stations support...
4. USING THE DEVICE 4.1. Putting the device under tension Switch on the main interrupter of the device. On the keypad, the white LED will go on. Display shows: POWER OFF. 4.2. Turning on the device Switch on the module by pressing key Select the required mode on the control panel according to the Shrinkfit holder front end type (see §...
The access code and the procedure to modify the heating times are given on request and after complete information about the risks. Any change of the preset time must be made carefully, toolholder overheating makes it unusable. In case of modification without our agreement, Seco Tools AB. cannot be held as responsible for any damage.
Page 15
Selection of the unit mm, inch, or mm and inch with mode PRG 1 or PRG 2: • On the control panel, select mode PRG 1 or PRG 2 (see § above) Press two times key Choose between mm, inch, or mm and inch using key Press two times key to confirm and come back to working mode.
4.3.4. Preparation before shrinking cycle 1) Position the universal sliding support on the heating station. 2) Install on it the support ring that corresponds to the Shrinkfit toolholder’s taper. Please refer to the latest Machining Navigator ‘Tooling Systems’ or to the Machining Navigator ‘Update’...
In order to guarantee torque transmission and to increase service life of the tool, recommended values for shrinking depth must be respected. Find the minimum shrinking depth from the chart below (also on the device). Example for a Seco toolholder type 5603 The diameter d and the jauge length are indicated on the toolholder:...
2) Select the appropriate heating mode (see § 4.3.2 for details). 3) Start the heating cycle by pressing key . Display is flashing during the heating cycle. The heating stops automatically at the end of the preset time or by pressing the key .
4.6. Shrinking of tools with larger front than shank Wearing supplied protective gloves is imperative while handling the device and Shrinkfit holders/tools. 4.6.1. Clearance between tool head and toolholder front face Note: For tools with larger front end than shank, split heat focusing stoppers covering tool shank diameter Ø...
After shrinking, remove the lock ring and move the inductor housing downwards, exposing the split heat focusing stopper. Remove the split heat focusing stoppers (caution: they may be hot). Move the inductor housing upwards to allow the toolholder to be removed. Note: Overall height of the inductor housing limits «...
Any change of the preset time must be made carefully. In case of modification without our agreement, Seco Tools AB. cannot be held as responsible for any damage. Once you have been provided with the code by your Seco representative, follow this procedure:...
Keep the device and its environment clean, to insure a long service life. • The device can only be used for the purposes defined in this operating book. Seco Tools AB. cannot be held as • responsible for casualties caused for any other use.