3. Technical data

WARNING:
If the pump is operated outside the specific limits, the pump housing may become
hot.

3.1 Operating and storage conditions

Table 1 Operating and storage conditions
Ambient temperature range (operation)
Maximum surface temperature of pump body
under normal operating conditions and maxi-
mum ambient temperature
Maximum humidity (operation)
Ambient temperature range (storage)
Pollution
Installation
Altitude restriction
Area of use

3.2 Performance

Table 2 General characteristics
Maximum pumping speed
Maximum permitted continuous inlet pressure
Maximum permitted continuous exhaust pres-
sure
Maximum permitted gas ballast inlet pressure
Maximum chamber volume to pump down from
atmospheric pressure
Maximum chamber volume for cyclic duty‑maxi-
mum 6 cycles per hour
Maximum initial pressure rise with no gas bal-
last flow
Suck‑back protection
Leak tightness
Maximum displacement
A73001880_N
A73001880_N - Technical data
Page 12
+ 10 °C to + 40 °C
+ 40 °C to + 65 °C
90% RH
- 30 °C to + 70 °C
Pollution degree 2
Installation category II
UL/CSA approved maximum 2000 m
(3000 m for E variant self certified)
Indoor use
3
35 m
/h
40 mbar
(1000 mbar for E variant)*
0.2 bar (g)
0.5 bar (g)
100 litres†
50 litres†
5 mbar l
By exhaust valve
-6
-1
< 1 x 10
mbar l s
3
44 m
/hr
11/2020 - ©Edwards Limited