Ethernet Expansion Board" Accessory Board; Pmu Expansion Board" Accessory Board - ABB TRIO-5.8-TL-OUTD-S Product Manual

Table of Contents

Advertisement

"

ETHERNET Expansion Board" accessory board

R 2 8
R 2 9
R 3 0
T P 5
R 3 1
R 3 2
R 1
R 3 3
R 2 2
C 1
R 3 4
R 2 3
R 2
D 4
C 1 2
R 3
R 2 4
R 4
C 1 1
R 5
C 2 1
R 6
L 1
R 7
R 3 5
T P 3
L 2
R 3 6
T P 4
C 1 3
R 3 7
R 8
R 2 5
T P 6
R 2 6
R 2 7
R 9
C 4 3
L 3
T P 7
R 5 2
R 5 8
C 1 4
C 4 4
R 1 0
T P 2
R 1 1
R 5 9
5
R 1 2
R 6 7
T P 2
C 4 5
R 6 8
C 1 5
R 6 0
C 3 6
C 3 7
R 5 3
R 5 4
C 2 5
X T A
L 3
C 1 0
C 3 4
C 3 9
R 4 5
C 3 8
R 4 6
C 4
R 1 9
R 1 7
C 3 2
C 2 8
C 4 0
R 4 9
D 1
R 1 5
R 5 5
C 3 5
R 5 7
C 4 1
R 1 4
C 4 8 R 6 1
C 1 9
C 4 7
C 2 0
C 2 2
2
1
8
7
Installing the "ETHERNET Expansion Board" makes it impossible to use the "
" accessory because both use the same wiring connector on the inverter.
Logger Card
"

PMU Expansion Board" accessory board

J 6
The Ethernet board is an accessory that allows you the possibility of con-
necting to the LAN for inverter monitoring; this may be done locally, with
direct connection to the PC, by accessing the internal web server; or
remotely, with internet connection to the through a router, to the portal
"Aurora Vision Plant Viewer/Aurora Vision
The code to use when ordering the accessory is: ETHERNET Expan-
sion Board
POWE
R
POWE
R
ALAR
M
ALAR
M
GFI
GFI
ESC
ESC
UP
UP
DOWN
DOWN
ENTE
R
ENTE
R
Ethernet
Ethernet
Install the Ethernet board to the interior of the inverter (to the connector
named SLOT 1
which can be found on the communication and control
27
board
).
06
The PMU board is an accessory which allows you to add additional fun-
ctionality to the inverter:
• PMU - Ability to remotely control reactive power and active power limi-
tation by the grid or system manager.
• Analogue inputs - Allows you to connect up to 4 analogue sensors (AN1,
AN2, AN3, AN4) and a PT100 or PT1000 sensor.
Inputs AN3 and AN4 can be used to control the PMU functions. In
this case the number of environmental sensors which can be con-
nected is 2 (AN1 and AN2)
• Analogue sensors power supply (16Vdc)
• RS485 serial line communication which can be used with a ModBus
RTU communication protocol.
The code to use when ordering the accessory is: PMU expansion board
Install the PMU board to the interior of the inverter (to the connector na-
med SLOT 2
which can be found on the communication and control
28
board
).
06
- 19 -
2 - Characteristics
".
®
POWE
R
ALAR
M
or
GFI
ESC
UP
DOWN
ENTE
R
Router
Ethernet
INTERNET
VSN300 Wifi

Advertisement

Table of Contents
loading

This manual is also suitable for:

Trio-7.5-tl-outd-sTrio-8.5-tl-outd-s