InfiniBand Switch Platform Hardware User Manual
2.1.5

Management Module LED Indicators

STATUS
The management module LEDs display the switch system operating conditions.
Table 11 - LEDs Display for Normal Operation
LED Condition
STATUS
This LED
shows the sta-
tus of the chas-
sis.
PSU STATUS
SPINE FANS
STATUS
LEAF FANS
STATUS
MASTER
Mellanox Technologies

Figure 51: Management Module Status Indications

12C
Off – No Power
Green – System is up and running.
Yellow – System warning. Attention needed (such as overheating).
Red – System not operational (Diagnostics fail, CPU hang,
HW fail, Overheat-critical)
Blinking green – System booting / Restore factory defaults in progress.
Off – No power
Green – Normal operational
Red – PS fault detected. User should check individual power supplies
for fault indications.
Off – No power to fan
Green – Nominal operational
Red – One or more of the spine fans is bad. User should check
individual spine fan LEDs for fault indications
Off – No power to fan
Green – Nominal operational
Red – One or more of the leaf fans is bad. User should check
individual leaf fan LEDs for fault indications
Off – this management module is not the master MM
Green – Management module is operating as a master (i.e., the other
management module is a slave)

Figure 52: Management Module LEDs

S
L.FANS
Master
MGT
CONSOLE
Description
MAC
Normal
State
Green
Green
Green
Green
Green
61