Figure 31: Intact Vs Defected Signal Connectors; Figure 32: Intact Vs Defected Power Pin Holders - Mellanox Technologies MSX6506-3R Hardware Installation Manual

108-port infiniband fdr switchx switch platform
Table of Contents

Advertisement

InfiniBand FDR Switch Platform Hardware User Manual
1. Check for foreign objects in or mechanical damage to the chassis leaf slots.
2. Check leaf mechanics for any noticeable damage.
3. Check back signal connectors' integrity. Look for any broken signal dividers or any
deviations from the pass criterion shown in Figure 31.
4. Check power connector's integrity. Look for any damage on the power connector
casing or blades damage, or any deviations from the pass criterion show in Figure 32.
5. Start with the ejector handle fully open; that is, at 45 degrees to the front panel of the
leaf.
6. Holding the leaf by its sides, carefully set the leaf board into the chassis.
Mellanox Technologies

Figure 31: Intact vs Defected Signal Connectors

Pass

Figure 32: Intact vs Defected Power Pin Holders

Pass
Fail
Fail