Datalogic Gryphon Series Product Reference Manual page 261

General purpose handheld area imager bar code reader
Hide thumbs Also See for Gryphon Series:
Table of Contents

Advertisement

References
ACK NAK Timeout Value
This option specifies the amount of time the reader waits for an ACK character from the host
following label transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15
seconds) in 200ms increments. A selection of 0 disables the timeout.
To set this value:
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 200 (setting is in 200ms increments). Pad the result with
3. Go to
4. Scan the bar code: SELECT ACK NAK TIMEOUT VALUE SETTING.
5. Scan the appropriate two digits from the keypad in
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming
This completes the procedure. See
Table 28. ACK NAK Timeout Value Setting Examples
STEP
ACTION
1
Desired Setting
2
Divide by 200
3
4
Scan Two Characters From
5
Appendix D, Keypad
6
258
leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
page 51
and scan the ENTER/EXIT PROGRAMMING MODE bar code to enter
Programming Mode.
the duration which was determined in the steps above. You will hear a two-beep indica-
tion after the last character.
If you make a mistake before the last character, scan the CANCEL bar code
to abort and not save the entry string. You can then start again at the
beginning.
Mode.
200ms
01
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT ACK NAK TIMEOUT VALUE SETTING
'0' and '1'
Scan ENTER/EXIT PROGRAMMING MODE
Appendix D,
Table 28
for some examples of how to set this feature.
EXAMPLES
1,000ms (1 sec.)
5200ms (5.2 sec.)
05
'0' and '5'
Gryphon™ I GD44XX/GBT4400/GM440X
Keypad, that represent
15,000ms (15 sec.)
26
75
'2' and '6'
'7' and '5'