Incomplete Array

An incomplete array results from a physical drive that fails or becomes missing
during:
RAID level migration under NVRAM
Physical drive transport
See "Physical Drive Failed" on page 273 for more information.
When VTrak discovers an incomplete array, WebPAM PROe displays a dialog
box asking you to:
Click the OK button to accept the incomplete array
Click the Cancel button to reject the incomplete array
Before you accept the incomplete array, be sure all of the physical drives are
present and that their drive carriers are properly installed into the enclosure. See
"Installing Disk Drives" on page 16.
If you choose to accept the incomplete array:
1.
Click OK in the incomplete array dialog box.
2.
Check the operational status of the logical drives in the array.
If the logical drives are critical or degraded, proceed with a rebuild.
See "Rebuilding a Disk Array" on page 114 or page 154.
If the logical drives are offline, contact Technical Support.
See "Contacting Technical Support" on page 285
3.
Restore your data from a backup source, if required.
The CLU displays the option Accept Incomplete Array on the Disk Array Info and
Settings screen. Highlight the option and press Enter to accept the incomplete
array.
If you choose NOT to accept the incomplete array:
1.
Click Cancel in the incomplete array dialog box.
2.
Do one of the following:
Delete the array. See "Deleting a Disk Array" on page 109 or page 151.
Replace the missing physical drive.