Promise Technology VTrak M610i Product Manual page 277

Hide thumbs Also See for VTrak M610i:
Table of Contents

Advertisement

Reported Event
Previously configured disk
is no longer found
A physical disk has
encountered an unknown
(non-ECC) media error.
A physical disk has
encountered PFA
condition
A configured dead
physical drive has been
inserted
A physical drive page 0/1
settings have been
changed
Physical disk is marked
as dead due to removal/
failure of reassign
sectors/PFA condition/
forced offline state
PSU (Power Supply Units)
PSU is not inserted/has
been removed
PSU is off
PSU is on
PSU is installed/
operational and turned on
PSU is installed/
operational and turned off
PSU is malfunctioning
and turned on/off
PSU 12V/5V/3.3V power
is out of the threshold
range
PSU 12V/5V/3.3V power
is within the range
Disk drive may have failed or was removed from the
enclosure. Replace or reinstall the disk drive as
needed.
Disk drive experienced an unknown error. If this
message appears repeatedly, replace the disk drive.
A potentially faulty address or bad sector was found.
The disk drive inserted into the VTrak was marked as
dead and will not work on the VTrak. Replace the disk
drive.
Result of settings or user action. Normal.
Replace the disk drive.
A power supply unit is missing from the VTrak.
Reinstall the power supply unit.
A power supply unit is present but turned off. Turn on
he power supply.
Normal.
Normal.
A power supply unit is present but turned off. Turn on
he power supply.
Replace the power supply unit.
Replace the power supply unit.
Normal.
263
Chapter 8: Troubleshooting
Corrective Action

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vtrak m310iVtrak m210i

Table of Contents