Promise Technology VTrak M610i Product Manual page 278

Hide thumbs Also See for VTrak M610i:
Table of Contents

Advertisement

VTrak M610i, M310i, M210i Product Manual
Reported Event
PSU Fans
PSU fan has turned on.
PSU fan has turned off.
PSU fan speed increased. Check the VTrak for overheating. See page 275.
PSU fan speed
decreased.
PSU fan is malfunctioning Replace the power supply. See page 204.
PSU fan is functioning
normally
PSU fan status is
unknown.
RAID Level Migration
RAID Level migration is
started
RAID Level migration is
completed
RAID Level migration is
paused
RAID Level migration is
resumed
RAID Level migration is
stopped
RAID Level migration has
encountered a physical
disk error
RAID Level migration is
aborted due to an internal
error.
RAID Level migration is
queued
Normal.
Verify that the power supply is turned on. If the fan
still does not turn, replace the power supply. See
page 204.
Temporary overheat condition was corrected.
Normal.
Check for airflow out of the power supply. If there is
none, check for proper installation and turn the power
supply on.
Result of settings or user action. Normal.
Normal.
Migration paused because of user intervention,
schedule or a higher priority background activity.
Migration has resumed again after a pause.
Migration stopped because of user intervention,
schedule or the logical drive was deleted or went
critical or offline.
Bad block found on a disk drive. Migration will finish.
Check the disk drive check table after migration and
replace disk drive as needed. See page 123.
System resources are low. Reduce system load or
restart the VTrak. See page 90.
Migration has been set manually or by schedule.
264
Corrective Action

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vtrak m310iVtrak m210i

Table of Contents