2.11 Wiring the Circuit under Measurement When Using a Voltage or Current Transformer
Connecting to the WT332E/WT333E
In the wiring examples that follow, the WT332E/WT333E input elements, voltage input terminals, and
current input terminals are simplified as shown in the following figure.
WT332E/WT333E
Also, the wiring examples are for when a CT is connected. When connecting a pass-through CT or a
clamp-type current sensor that outputs current, substitute the CT with the pass-through CT or clamp-
type current sensor.
L CT
C
Input element
IM WT310E-02EN
Voltage input
terminals
Current input
terminals
Input element
±
V
±
±
VOLTAGE
CURRENT
±
V
EXT
C
±
±
Pass-through CT
±
V
C
±
Input element
Clamp-type current
sensor that outputs
current
±
V
C
±
Input element