Press ωc to set the upper limit frequency. For setting methods, refer to
descriptions in "Parameter Setting Method".
Press More → AutoSetting to adjust the vertical scale and offset of the
operation results to an optimal value based on the current configuration, so as
to better observe.
Press More → Invert to enable or disable the inverted display function of the
waveform.
Press More → Label to set the label for math operation results. For details,
refer to descriptions in "Math Operation Label".
Press More → Color Grade to enable or disable the color grade display of the
operation results. When enabled, different colors are displayed on the screen to
indicate the times of data acquisition or acquisition probability.
Press More → Reset ColorGrade to clear the color grade display and display
the color grade again.

High Pass

Only allows the signals whose frequencies are higher than the current lower limit
frequency to pass.
Press Math → Math1 → Operator to select "HighPass":
Press Operation continuously to enable or disable the "HighPass" operation
function.
Press SourceA, and rotate the multifunction knob
Source A. Then press down the knob to select the channel. You can also press
SourceA continuously or enable the touch screen to select the channel. The
available channels for Source A are CH1-CH4 and Ref1-Ref10.
Note:
The available channels for Math2 are CH1-CH4, Ref1-Ref10 or Math1.
The available channels for Math3 are CH1-CH4, Ref1-Ref10, Math1 or Math2.
The available channels for Math4 are CH1-CH4, Ref1-Ref10, Math1, Math2 or
Math3. Only the channels that have been enabled currently can be selected.
Press Offset to set the vertical offset of the operation results. For setting
methods, refer to the descriptions in "Parameter Setting Method". You can
also enable the touch screen and use the "Drag" gesture to adjust the vertical
offset.
Press Scale to set the vertical scale of the operation results. For setting methods,
refer to the descriptions in "Parameter Setting Method". You can also enable
the touch screen and use the "Pinch & Stretch" gesture to adjust the vertical
scale.
Press ωc to set the lower limit frequency. For setting methods, refer to
descriptions in "Parameter Setting Method".
Press More → AutoSetting to adjust the vertical scale and offset of the
6-22
Chapter 6 Operations and Measurements
to select the channel for
MSO5000 User Guide