2N IP Style 9157101 Installation Manual page 66

Table of Contents

Advertisement

Installation:
®
Install 2N
Security Relay onto a two-wire cable between the intercom and the electric lock
inside the area to be secured (typically behind the door). The device is powered and controlled
via this two-wire cable and can thus be added to an existing installation. Thanks to its compact
dimensions, the device can be installed into a standard mounting box.
Connection:
® 
Connect 2N
Security Relay to the intercom as follows:
To the active output (OUT1)
Connect the electric lock to 2N
To the switched output
To the passive output in series with the external power supply
The device also supports a Departure button connected between the 'PB' and '- HeliosIP / IP
Intercom terminals. Press the Departure button to activate the output for 5 seconds.
Status Signaling:
Green LED
flashing
on
flashing
on
Configuration:
®
Connect 2N
Security Relay to the properly set Security intercom output. Refer to the
Configuration Manual for 2N IP Intercoms for details. Make sure that one LED at least is on or
flashing.
Press and hold the 2N
programming mode (both the red and green LEDs are flashing).
®
Security Relay output as follows:
Red LED
off
off
flashing
flashing
®
Security Relay Reset button for 5 seconds to put the device in the
Installation Manual 2N® IP Style
Status
Operational mode
Activated output
Programming mode – waiting for
initialization
Error – wrong code received
66 /  88