Available Switches
Location
Basic Unit
I/O* Module
(Part No. 9155034)
You can use any number of the modules marked with *.
Name
RELAY
OUT
ext.relay1
ext.relay2
Installation Manual 2N® IP Style
Description
Passive switch: make and break contact,
up to 30 V / 1 A AC/DC Used for connection
of non-critical devices only (lights, e.g.).
Active switch
output: 8 to 12 V DC
according to power supply (PoE: 10 V;
adapter: source voltage minus 2 V), up to
600 mA
Passive switch: make and break contact,
up to 30 V / 1 A AC/DC Used for connection
of non-critical devices only (lights, e.g.).
Passive switch: make and break contact,
up to 30 V / 1 A AC/DC Used for connection
of non-critical devices only (lights, e.g.).
44 / 88