ID or PIN code. All the inputs and outputs are galvanically isolated from the 2N
with insulation strength of 500 V DC.
•
The module contains two VBUS connectors for device bus connection.
•
These two connectors are interchangeable and can be used either as inputs from the basic
unit or outputs to other modules.
•
If this module is the last one on the bus, one of the connectors remains unconnected.
•
The module package includes a 80 mm long interconnecting cable.
The module also includes:
•
Isolated OSDP bus
•
Power and pairing mode signaling LED
•
Tamper switch (9155038) input
Installation Procedure
Having connected the OSDP module to 2N
the module. The OSDP module uses the RS-485 bus for the interface.
Connect the OSDP device as instructed (A to B or B to A) keeping the correct order to avoid
malfunction.
Installation Manual 2N® IP Style
®
IP Verso via the VBUS, connect the OSDP device to
®
IP Verso system
63 / 88