Alpha ESS SMILE-G3-S5 Manual page 66

Hide thumbs Also See for SMILE-G3-S5:
Table of Contents

Advertisement

63
Error No.
Error description
battery_stops_
110005
running_alarm
overtempera-
110006
ture_alarm
10.2.2 Battery Protection Description
LED Indictor
Yellow LEDs
flash once per
second.
LED
Error Code
Display
1
3
4
5
6
8
9
11
MAINTENANCE AND TROUBLESHOOTING
Solution
1. If the battery is not connected, use a multimeter
to measure whether there is voltage at the battery
terminal.
2. Restart the inverter to see if the fault still exists.
If it still exists, please call the service center.
1. Try to lower the ambient temperature.
2. Make sure that the inverter is installed according
to the manual and there is no shelter around the
machine.
3. After the inverter is powered off and waiting for
30 minutes, then restart it. If the fault still exists,
please call the service center.
Description
Wait for automatical recovery.
If the problem is not be solved
Temperature
yet,please call the service
difference
center.
Stop discharging and charging
until this code is eliminated and
Hardware error
wait for the temperature to
drop.
Stop discharging until this code
Low
is eliminated and wait for the
temperature
temperature to rise
discharge
Over-current
charge
Wait for automatical recovery.
If the problem is not be solved
Over-current
yet, please call the service
discharge
center.
Cell
overvoltage
Cell under
Stop discharging and call the
voltage
service immediately.
Stop discharging until this code
Low
is eliminated and wait for the
temperature
temperature to rise.
charge
Troubleshooting

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smile-g3-s3.6Smile-g3-b5

Table of Contents