23
7. Tighten the wall bracket and the battery pack with screw M5*12 (X 2) (tool: T20
screwdriver, torque: 2.5Nm).
If the floor of installation site is uneven, please use floor gaskets to level at the
bottom of the battery pack
WARNING
Risk of injury when lifting the battery pack, or if it is dropped
The Battery Pack is very heavy. There is risk of injury if the battery pack is lifted
incorrectly or dropped while being transported or when attaching it to or removing it
from the wall bracket.
Transport the battery pack always as described below.
It is forbidden to stack 3 batteries from top to bottom.
8. Mounting more batteries
You can install extra batteries up to 6 batteries in a system.
Please install extra batteries by side, also batteries can be stacked up to two bat-teries
per column. Expansion wiring please refer to Chapter 7.8.
1) If you will install extra batteries by side, please repeat steps 1-6 and keep the
distance between two batteries greater than 300mm. The space between the left and
the right battery is a recommended distance. Keep the distance as short as you can if
there is no influence to the operation.
gasket