Storage Temperature:
THERMAL MANAGEMENT CENTER
VACUUM AND AIR
Measurements at front panel SNAP-VAC and Controllable PRESSURE Ports of power source.
Vacuum Rise Time:
Vacuum:
Pressure:.
Air Flow:
TEMPERATURE SPECIFICATIONS
Tip Temperature Range: 38°C to 482°C (100°F - 900°F) (see note).
Digital Readout Resolution:
Tip Temperature Stability:
True minimum and maximum Operating Tip Temperatures may vary
depending on handpiece & tip selection.
EOS/ESD
Tip-To-Ground
Resistance:
AC Leakage:
-40°C to 100°C (-40°F to 212°F).
Evacuates 33 cc (2 cubic inches) volume
to 25 cm Hg. (10 in. Hg.) in 150 ms.
51 cm Hg. (20 in. Hg.) (nominal)
48 Bar (7 P.S.I.) (nominal MAX setting)
13 SLPM (0.46 SCFM) maximum.
± 1° (°C or °F)
± 1.1 °C (2°F) at idle from Set Tip Temperature.
NOTE
Less than 5 ohms.
Less than 2 millivolts RMS from 50Hz to 500Hz, min.