Pace PRC 2000 Operation & Maintenance Manual page 41

Hide thumbs Also See for PRC 2000:
Table of Contents

Advertisement

Refer to "Tip & Temperature Selection" for a complete discussion of Tip
Temperature Offset function.
10. Press the TIP OFFSET Key once to enter TIP
OFFSET Mode. Immediately press and hold the
Scroll Up Key. Observe the displayed TIP OFFSET
CONSTANT increase, first in 1° and then in 10°
increments. Release the Scroll Up Key when the
Digital Readout reads "33" for °C ("60" for °F).
If the Digital Readout displays "P - -", a pass-
word has been previously installed. Enter the
password at this point to continue. Refer to the
"Password" portion of this manual for details on
password operation.
11. While still in the TIP OFFSET Mode (TIP OFFSET
LED flashing) press and hold the Scroll Down Key.
Observe the displayed TIP OFFSET CONSTANT
decrease first in 1° and then in 10° increments.
Release the key when the Digital Readout displays
"28" for °C ("50" for °F).
12. Immediately press the TIP OFFSET Key to exit the
TIP OFFSET Mode and enter the new TIP OFFSET
CONSTANT for the Current Channel into the system
memory. Notice that the TIP OFFSET LED remains
illuminated (not flashing). ONLY IF A CURRENT
CHANNEL HAS A TIP OFFSET CONSTANT
GREATER THAN THE DEFAULT ("3" for °C or "6" for
°F) DOES THIS LED REMAIN ILLUMINATED. The
system will retain stored Set Tip Temperatures and
TIP OFFSET CONSTANTS even when power is
removed.
NOTE
NOTE
Figure 31. Increase Tip Offset Value
Figure 32. Decrease Tip Offset Value
Figure 33. Store Tip Offset Value
41