GX8 Manipulator 3. Environments and Installation
the following things.
-
-
-
-
-
-
-
-
■ Use an earth leakage breaker on the AC power cable of the Controller to avoid
electric shock and circuit breakdown caused by short circuit.
Prepare the earth leakage breaker that pertains the Controller you are using.
WARNING
For details, refer to the Controller manual.
■ When cleaning the Manipulator, do not rub it strongly with alcohol or benzene.
It may lose luster on the coated face.
CAUTION
120
The model complies with grade of protection IP65 (IEC 60529, JIS C0920). The
Manipulator can be installed in an environment where dust is flying or where it is
exposed to water.
The Manipulator can be installed in an environment where dust, oily smoke, metal
powder, etc. are floating in the air. However, any contaminants that can deteriorate
sealing performance of nitrile rubber oil sealing, O-rings, packing seals and liquid
gasket should be avoided.
The Manipulator cannot be used in environments where include corrosive liquids and
droplets such as acid or alkaline.
In an environment where it is exposed to salty droplets, the Manipulator is susceptible
to rust.
The surface of the Manipulator has general oil resistance. However, if your
requirements specify that the Manipulator must withstand certain kinds of oil, please
contact the supplier of your region.
Rapid change in temperature and humidity can cause condensation inside the
Manipulator.
If your requirements specify that the Manipulator handles food, please contact the
supplier of your region to check whether the Manipulator will damage the food or not.
The controller used with the Protected-model Manipulator does not have protection
features for dusty, wet, or oily environment. The controller must be placed in an
environment that meets the specified conditions.