A.3 Connecting Cables
A.3.1 SCSI Cables
A.3.2 Ethernet Cables
A.3.3 Video Cables
The SCSI cables for the internal devices are connected at the factory. If you are
installing additional devices in the device tray, refer to the device installation
instructions that accompany the storage device.
The main network cable must be connected to the on-board Ethernet connector
on system board 0. Refer to Chapter 2 of this manual and to the instructions
that come with your Ethernet transceivers for additional information.
The SPARCserver 1000 system supports twisted-pair Ethernet installations.
Only one CGSIX interface is allowed per system. It must be installed in SBus
slot 1 of system board 0. The keyboard must be plugged into the keyboard
connector of system board 0 and the video cable into the GCSIX card.
The diagnostic program requires a monitor or terminal. If the system lacks a
monitor, an RS232 TTY terminal must be plugged into port A of the system
board in slot 0.