Installation Space - Panasonic LP-S Series Maintenance Manual

Laser marker
Hide thumbs Also See for LP-S Series:
Table of Contents

Advertisement

2-3-4 Installation space

For the appropriate air cooling, provide space around the device as shown in the following figure.
„ Head
LP-Sxxx
50mm
150mm
LP-SxxxW
50mm
150mm
• To maintain the air-cooling performance of the laser marker, install both the head and controller in a well-ventilated
place.
• Installing near a heating element could cause the ambient temperature exceeding the specification range, which may
cause malfunction of the product.
• When setting more than one laser marker, install them so that a space of 300 mm or more is given between the heads of
each marker. Not doing so may cause malfunction. It might cause the malfunction with the laser marker.
• Ensure the minimum bent radius of each cable.
56
500mm
50mm
300mm
50mm
„ Controller
q
50mm
150mm
ME-LPS-SSM-8
w
300mm
50mm
Intake air
q
Exhaust
w

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents