4-2-9 Power monitor calibration

[Function specific to LP-SxxxW type]*
After the installation, replacement or moving of laser marker, the accuracy of the power monitor measurement result may
decrease. In that case, calibrate the power monitor. When the power monitor calibration is performed, the measurement is
shown assuming the power at that point to be 100%.
CAUTION
1.
Press [POWER CHECK].
2.
The Confirm screen is displayed.
Press [START].
The current laser power is measured.
• Power check function is available when laser pumping is completed.
3.
The Power Monitor screen is displayed.
Press [CALIBRATE].
4.
The Password input screen is displayed.
Enter the password and press [OK].
Password: 1973 (fixed)
5.
Press [EXECUTE].
The power monitor is calibrated.
By clicking [INITIALIZE], the calibration of the power monitor is reset to the
delivery state.
• Once the power monitor is calibrated, the previous corrected values are cleared. Execute the power check again and
input the correction rate if needed.
• The ±10% difference might be occurred under the high/low temperature. Correcting power with normal temperature (20
to 30 Celsius degree) is recommended.
• Power monitor cannot be calibrated from "Laser Marker NAVI plus".
140
This function is not implemented in the LP-Sxxx type
• Laser is radiated with the internal shutter closed. Just in case, be sure to use
the protective goggle and enclosure. Also, do not place the work around the
radiating area.