Panasonic LP-S Series Maintenance Manual page 31

Laser marker
Hide thumbs Also See for LP-S Series:
Table of Contents

Advertisement

Item
Required time for laser pumping
Power voltage
Power consumption *10
Grounding method
Cooling method
Operating ambient temperature *11
Ambient temperature for storage *11
Operating ambient humidity *11
Protection degree *12
Overvoltage category
Pollution degree
Use location
Fiber cable length
Installation
direction
Main unit weight
Battery
(embedded in
product)
Quantity / Weight
*1 : Average output power from the laser marker at delivery time with the maximum laser power setting.
*2 : For the work distance, there is an individual difference of the following range in each product.
LP-S200 / LP-S202 / LP-S500 / LP-S502: Approx. ±0.5 mm
LP-S205 / LP-S505: Approx. ±2.0 mm
*3 : The value shown here is the configuration range that can be input. The setting values that can keep the quality of
marking or processing vary depending on the marking conditions and the target materials.
*4 : Depending on the marking data, the available scan speed might be limited in case the continuous marking more than
1 minute with high scan speed is set.
*5 : For using SQRC, an extra-cost software is needed. SQRC marking function is available only for use in Japan.
*6 : VEC is a usable format of graphic file for laser marker. To use HPGL, BMP or JPEG files, convert them to VEC format
with the attached "Logo Data Conversion software". To use AI or EPS files, convert them to VEC format with the
attached software "ExportVEC".
*7 : Check the performance and operation before use. Use a USB flash drive formatted with FAT32. USB media with
security features cannot be used.
*8 : OS versions of which Microsoft has ended support are excluded.
*9 : The power voltage is auto-switched.
*10 : The typical value of the inrush current at system startup is as follows. (Duration time is 10 ms or less.)
100V AC: 80A / 200V AC: 160A
*11 : This specification is applied to both head and controller. No condensation and freezing shall be allowed. If there is
a gap between the stored temperature and operating temperature, make sure to have the product get used to the
operating ambient temperature gradually prior to use to prevent the dew condensation.
*12 : For the oil proof condition, refer to "About protection grade (dustproofness, waterproofness and oilproofness)" (P.34).
LP-S200
100V AC
200V AC
Head
Controller
Head
Approx. 7.5kg
Controller
Type
Model
ME-LPS-SSM-8
Model
LP-S202
LP-S205
Approx. 20 seconds
90V to 132V AC or 180V to 264V AC
(including voltage fluctuation range of ±10%) *9
Frequency: 50/60 Hz
330VA or less
450VA or less
Head and controller: Direct earth
Head: Natural air-cooling, Controller: Forced air-cooling
0 °C to +40 °C
-10 °C to +60 °C
35 to 85%RH
Head: IP67G (excluding the controller)
Indoor; at an altitude of 1000 m or below
5 m +/- 0.2 m, minimum bent radius 70 mm
Omnidirectionally
Vertically or horizontally
Approx.
8kg
Approx. 24kg
Graphite fluoride lithium battery
BR-1 / 2AAC2P
1 piece / Approx. 9.5g
LP-S500
LP-S502
530VA or less
650VA or less
2
Approx. 7.5kg
Approx. 25kg
LP-S505
Approx.
8kg
31