3-5-10 Rank / external offset marking

ON
TRIG. IN
OFF
ON
SELECT 0 to 2 IN
OFF
ON
D0 to D15 IN *2
OFF
ON
SET IN
OFF
ON
READY OUT
OFF
ON
MARKING OUT
OFF
ON
SET OK OUT
OFF
Item
Period
T1
T2
0 ms or more
T3
2 to 510 ms
T4
T6
0 ms or more
T7
0.5 ms or more
*1 : Input SELECT 0 to 2 as the table below.
Number input target
Data No. of rank/external offset
*2 : Specify the data number of rank/external offset function by using D0 to D15. For details, see "3-3-4 Signals on I/O
connector" (P.94).
• SET IN for the rank/external offset is acceptable when the laser pumping is completed and the internal shutter is
opened.
• When the rank/external offset function is set, the ready output will not turn ON until the data number and SET input are
input.
• Enter the data number input and SET input every time for each marking trigger even there is no change to the marking
data.
• Close the shutter to reset the data number that was set.
• Do not input the SET input for the next data until the marking output turns on by inputting the marking trigger after
inputting SET input.
• The ready output will turn ON even when the marking data is not configured to the data number input.
• If the rank or external offset functions are used with the marking to the flying object, make sure that the marking interval
time is enough to the required period to input the marking data and to confirm the marking ready output.
114
*1
T2
Data A
T7
T2
T1
Data A
T3
Remarks
Time for data creation. It varies depending on the quantity of data to be marked.
Keep the inputs of SELECT 0 to 2 and the number until the SET OK turns on.
One-shot output. Set the output time on the environment setting screen. There is a
margin for the setting value.
• When T5 < T1 = T1 - T5.
• When T5 > T1 is 1 ms or less.
Turn ON the SET after MARKING is turned to ON.
After a lapse of 0.5ms or more from specifying SELECT 0 IN to SELECT 2 IN and D0 IN
to D15 IN, turn on SET IN.
SELECT 0 (No. 20)
ON
ME-LPS-SSM-8
*1
*1
T2
T2
Data B
Data C
T2
T6
T2
T1
T4
Data B
T3
SELECT 1 (No. 21)
OFF
T5
Data C
T3
SELECT 2 (No. 22)
OFF