Item
Power voltage
Power consumption
*10
Grounding method
Cooling method
Operating ambient temperature *11
Ambient temperature for storage *11
Operating ambient humidity *11
Protection degree *12
Overvoltage category
Pollution degree
Use location
Fiber cable length
Installation
direction
Main unit weight
Battery
(embedded in
product)
*1 : Average output power from the laser marker at delivery time with the maximum laser power setting.
*2 : Work distance reference position represents the calculated center position of the work distance range. Depending on
objects to be marked, optimal distance may vary.
*3 : Work distance range represents the configurable work distance. Depending on objects to be marked, optimal distance
or markable range may vary.
*4 : The value shown here is the configuration range that can be input. The setting values that can keep the quality of
marking or processing vary depending on the marking conditions and the target materials.
*5 : For using SQRC, an extra-cost software is needed. SQRC marking function is available only for use in Japan.
*6 : VEC is a usable format of graphic file for laser marker. To use HPGL, BMP or JPEG files, convert them to VEC format
with the attached "Logo Data Conversion software". To use AI or EPS files, convert them to VEC format with the
attached software "ExportVEC".
*7 : Check the operation before use. Use a USB flash drive formatted with FAT32. USB media with security features
cannot be used.
*8 : OS versions of which Microsoft has ended support are excluded.
*9 : The power voltage is auto-switched.
*10 : The typical value of the inrush current at system startup is as follows. (Duration time is 10 ms or less.)
100V AC: 80A / 200V AC: 160A
*11 : This specification is applied to both head and controller. No condensation and freezing shall be allowed. If there is
a gap between the stored temperature and operating temperature, make sure to have the product get used to the
operating ambient temperature gradually prior to use to prevent the dew condensation.
*12 : For the oil proof condition, refer to "About protection grade (dustproofness, waterproofness and oilproofness)" (P.34).
100V AC
200V AC
Head
Controller
Head
Controller
Type
Model
Quantity / Weight
LP-S500W
90V AC to 132V AC or 180V AC to 264V AC
(including voltage fluctuation range of ±10%) *9
Frequency: 50/60 Hz
470VA or less
650VA or less
Head and controller: Direct earth
Head: Natural air-cooling, Controller: Forced air-cooling
0 °C to +40 °C
-10 °C to +60 °C
35 to 85%RH
Head: IP67G (excluding the controller)
Indoor; at an altitude of 1000 m or below
5 m +/- 0.2 m, minimum bent radius 50 mm
Omnidirectionally
Vertically or horizontally
Approx. 6.5kg
Approx. 24kg
Graphite fluoride lithium battery
BR-1 / 2AAC2P
1 piece / Approx. 9.5g
ME-LPS-SSM-8
Model
LP-S505W
2
Approx. 7kg
33