Buttons - Deckma Hamburg OMD-2008 Series Instruction Manual

15ppm bilge alarm
Hide thumbs Also See for OMD-2008 Series:
Table of Contents

Advertisement

FW Flush can be switched on or off, respectively. At OMD-2008 EVFC the Flow
Measurement can be read. Also, cleaning interval at OMD-2008 EVA can be managed
from minimum 1 minute and maximum 8 hours. By "0" Autoclean will be off.
3. Data Logger Operation Buttons
The "Log" buttons are used to operate the integrated data logger. These buttons show a
live display, in which the current data from alarm status, the external separator
additionally, the oil content, the device status, and a reserve is recording to IMO
Requirements. That data can be shown as a graphical or a text-based recording at any
particular time. All the information will be recorded every 15 seconds. All recorded data
is available for more than 18 months.
With the arrow buttons the data can be navigated.
The internal clock is factory set for GMT, Greenwich Mean Time and cannot be changed
or adjusted. The internal clock is adjusted to be within +/- 2 minutes of GMT in production.
A few minutes of derivation per year of operation should be expected. (See section
Data Logger Operation Buttons
 See Section 22.
14.1

Buttons

Buttons
for more details.)
Appendix for more details about the buttons.
Pressing this button once, it is possible to return to the previous menu.
Pressing this button twice, it is possible to return to the "Normal Operation" display.
Navigates to the next or previous option.
Navigates to the next or previous option.
By pressing this button, it is possible to select and confirm entry.
Pressing this button, directly leads into the "SYSTEM TESTS" menu.
Pressing this button, directly leads into the "SYSTEM-OPTIONS" menu.
Pressing "AL1/2" buttons, leads into the "SETTING,def." menu.
Pressing this button, leads directly into the "SYSTEM info" menu.
Pressing this button once, leads into the "SETTING,def." menu. Pressing the button
twice leads into "DEFAULT" menu.
Pressing this button once, leads into the "DATA LOG live" menu, if the memory card
is activated. Pressing this button twice, the recorded data display mode will be
invoked and graphical recorded data appears. Pressing this button if a non-activated
memory card is inserted, leads to the menu to activate the memory card.
It is possible to press and slide the "Arrow" sliders (right/ left), to navigate to the data
or time of recorded data, in the graphical recorded data menu.
Page: 57 of 102
Description
22.3

Advertisement

Table of Contents
loading

Table of Contents