Terminal Description; Figure 20. Connection Example - Deckma Hamburg OMD-2008 Series Instruction Manual

15ppm bilge alarm
Hide thumbs Also See for OMD-2008 Series:
Table of Contents

Advertisement

9.

Terminal description

Terminals
Nomination
1-2
Power Supply
3-4
Pilot Voltage Output (Same as Power Supply)
5-7
Potential free Output Alarm 1 (Change over contact)
8-10
Potential free Output Alarm 2 (Change over contact)
11-12
Input Status Switch from Separator (Close when running)
13-14
Input Reserved for future use
15-16
Optional flow alarm input for external switch, ex works
linked
17-18
Signal Output 0 (4) to 20 mA
19-20
Input External Fresh Water Usage Request
21-22
Output External Fresh Water Usage Feedback
23-25
Potential free Output System Fault Alarm (Change over
contact)
Alarm contacts description is in alarm (non-

Figure 20. Connection Example

energized) condition.
POWER SUPPLY MUST HAVE
A FUSE T2A
POWER SUPPLY 24V-240V AC/DC.
EXAMPLE
Connections may vary
with different separator
control boxes.