Deckma Hamburg OMD-2008 Instruction Manual

15ppm bilge alarm
Hide thumbs Also See for OMD-2008:

Advertisement

I N S T R U C T I O N M A N U A L
15ppm Bilge Alarm
OMD-2008
Versions with
Electric Valve (EV)
Flow Control (FC)
Manual Cleaning Unit (MCU)
DECKMA HAMBURG GmbH
Kieler Straße 316, D-22525 Hamburg - Germany
Tel.: +49 (0) 40 54 88 76-0, Fax: +49 (0) 40 54 88 76-10
Internet: www.deckma.com
eMail: post@deckma.com
MOTEC
Marine & Offshore Technology

Advertisement

Table of Contents
loading

Summary of Contents for Deckma Hamburg OMD-2008

  • Page 1 Versions with Electric Valve (EV) Flow Control (FC) Manual Cleaning Unit (MCU) DECKMA HAMBURG GmbH Kieler Straße 316, D-22525 Hamburg - Germany Tel.: +49 (0) 40 54 88 76-0, Fax: +49 (0) 40 54 88 76-10 Internet: www.deckma.com eMail: post@deckma.com MOTEC Marine &...
  • Page 2 Alternatively the unit may be replaced by a calibrated 15 ppm Bilge Alarm. The OMD-2008 EVFC is designed in that way, that only the measuring cell needs to be changed, as this unit carries the Calibration Certificate. The Calibration Certificate with the date of the last calibration check should be retained onboard for inspection purposes.
  • Page 3: Table Of Contents

    13.1 Memory Card Calibration 14.1 Calibration and Repeatability Check 14.2 Function Test at Classification Survey and Port State Control Spare Parts 15.1 Recommended On Board Spares Remarks Issue: 08.07.2015 Instruction Manual OMD-2008 (EV, FC, MCU Versions) Page 2 of 28...
  • Page 4: Introduction

    DECKMA HAMBURG GmbH Introduction The OMD-2008 EV-FC Bilge Alarm Unit has been designed specifically for use in conjunction with 15 ppm oil-water separator units and has a specification and performance which exceeds the requirements of the International Maritime Organization specifications for 15ppm Bilge Alarms contained in Resolution MEPC.
  • Page 5: Principle Of Operation

    10 ppm or 5 ppm. An alarm point setting above 15 ppm is not possible. The adjustment can be done in the programming mode as described in Section 10.4. Issue: 08.07.2015 Instruction Manual OMD-2008 (EV, FC, MCU Versions) Page 4 of 28...
  • Page 6: Fc (Flow Control)

    Instrument will go to Alarm condition and issue a “Status: Flow?” message. EV (Electric clean water Valve) OMD-2008 EV instruments are equipped with an electric switchover valve for the clean water stream. The valve can be controlled via the menues, or remotely using the control input.
  • Page 7: Specification

    150 mm W x 290 mm H x 140 mm D Degree of Protection: IP 65 Weight: 5,9 kg Pipe Connections: for 6mm OD Cu or SS pipe Technical specifications are subject to change without notification Issue: 08.07.2015 Instruction Manual OMD-2008 (EV, FC, MCU Versions) Page 6 of 28...
  • Page 8: Construction

    It is mounted onto a stainless steel support that also holds the valve assembly and the Flow Sensor. An electric valve controls sample water and clean water usage. The OMD-2008 EV-FC can easily be mounted in wall or bulkhead installation. Computer Unit Flow Sensor...
  • Page 9: Installation

    20 s. Mount the OMD-2008 EV-FC Computer Unit by means of M6 or M8 screws on to a rigid vertical surface and preferably with the display panel of the monitor at eye level.
  • Page 10 Care must be taken at mounting of the pipes connections to avoid any torsion of the housing and damage of the instrument. Issue: 08.07.2015 Instruction Manual OMD-2008 (EV, FC, MCU Versions) Page 9 of 28...
  • Page 11: Piping

    Piping (REFER TO FIG. 3) Connect the OMD-2008 EV-FC Monitor to the sample point of the oily-water separator outlet and to a source of oil free water. Fittings on the Instrument are for 6 mm OD copper or stainless steel pipe. Adapter fittings for other pipe diameters are available upon request.
  • Page 12: Wiring

    (Terminals 1&2 via Fuse T2A). The pilot voltage can be used to supply additional external circuitry, e.g. alarm lamps or electrical valves. Issue: 08.07.2015 Instruction Manual OMD-2008 (EV, FC, MCU Versions) Page 11 of 28...
  • Page 13 Alarm contacts description is in alarm (non-energized) condition. Note: In case the OMD-2008 EV-FC is installed as replacement to a MEPC.60(33) approved separator and no “Status Separator” signal is available, a link across terminal 11 + 12 can be installed. Alternatively a “Status Separator”...
  • Page 14: Typical Control System

    The unit is designed for a power supply of 24 V to 240 V AC or DC. It has an automatic voltage selection. The power supply must have a fuse rated no more then 2A. Issue: 08.07.2015 Instruction Manual OMD-2008 (EV, FC, MCU Versions) Page 13 of 28...
  • Page 15: Commissioning

    Minute. Flow rate for both smaple stream and clean water stream should be approx. 2 Liters per Minute. b) On OMD-2008 EV-FC instruments adjust the flow rate through the unit by using the small O-Rings in the cell cap.
  • Page 16: Functional Tests

    If the sample flow rate is too small, the instrument will be in Alarm and display “Status: Flow”. On instruments fitted with Manual Cleaning Unit (OMD-2008 EV-FC MCU), sample a higher or a lower flow rate can be adjusted. To get the higher flow rate, remove the smaller O-Ring (9.5x2) from the Manual Cleaning Unit.
  • Page 17: Programming Mode

    Refer to Fault finding table in Pressing the button will manual for explanations of display more detailed information status information. about the current status. Issue: 08.07.2015 Instruction Manual OMD-2008 (EV, FC, MCU Versions) Page 16 of 28...
  • Page 18 To reset to to reset all settings to the factory values once again press factory default settings. button. Issue: 08.07.2015 Instruction Manual OMD-2008 (EV, FC, MCU Versions) Page 17 of 28...
  • Page 19 Flow rate and status of the meter is displayed. Exit from Flow display by pressing the ESC button. Issue: 08.07.2015 Instruction Manual OMD-2008 (EV, FC, MCU Versions) Page 18 of 28...
  • Page 20 In both data display modes the arrow buttons can be used to navigate to another date/time of recorded data. Issue: 08.07.2015 Instruction Manual OMD-2008 (EV, FC, MCU Versions) Page 19 of 28...
  • Page 21: Operating Instructions

    Whenever clean water is used, the instrument will be in Alarm condition. The OMD-2008 EV-FC has an additional Flow Sensor to detect the flow rate of the water through the instrument. If the sample does not flow, the instrument will be in alarm condition.
  • Page 22: Operator Maintenance

    Please note that a desiccator package should never be opened unless it is installed immediately. j) Switch electric valve to SAMPLE setting. Issue: 08.07.2015 Instruction Manual OMD-2008 (EV, FC, MCU Versions) Page 21 of 28...
  • Page 23 NB: The Manual Cell Clean Unit may also be used during normal operation with sample water, but in this case an alarm occurs because the wiper is passing the light source. Spares: Wiper Seal DH 77606 Issue: 08.07.2015 Instruction Manual OMD-2008 (EV, FC, MCU Versions) Page 22 of 28...
  • Page 24: Important Information: Cleaning Of Glass Tube

    DECKMA HAMBURG GmbH Important Information! Cleaning of Glass Tube at 15 ppm Bilge Alarms OMD-2008 series IMPORTANT: NEVER DISASSEMBLE THE UNITS AS THIS MAY VOID THE CALIBRATION AND THE CERTIFICATION! CLEANING HAS ONLY TO BE DONE TROUGH THE REMOVED CELL CAP BY...
  • Page 25: Fault Finding

    Fault finding See Section 2 for important notes. The OMD-2008 EV-FC will indicate several malfunctions in the status line of the display. Pressing the “OK” button will lead into an information window, similar to the items listed in the table below.
  • Page 26: Memory Card

    Under normal use the card should not be taken out, as this is linked with the specific system. The card can be read in other OMD-2008 units, but writing is only possible in the related system.
  • Page 27: Calibration And Repeatability Check

    Note that this test will only switch the alarm contacts to non-alarm condition, if the sample contains less than 15ppm oil content and all other conditions for proper measurement are OK. Issue: 08.07.2015 Instruction Manual OMD-2008 (EV, FC, MCU Versions) Page 26 of 28...
  • Page 28: Spare Parts

    Wiper Seal for Cell Clean Unit 77606 OMD-CR Memory Card Reader 75185 Function Test Kit 18510 Flow Sensor 16700 15.1 Recommended On Board Spares DESCRIPTION ART-NUMBER 1 off Service Kit 18570 Issue: 08.07.2015 Instruction Manual OMD-2008 (EV, FC, MCU Versions) Page 27 of 28...
  • Page 29: Remarks

    All the modifications and deviations from the standard form, which have to be carried out in the supply, should be attached at this paragraph. Commissioned on: ......by: .......... Date Firm's Name Remarks: Issue: 08.07.2015 Instruction Manual OMD-2008 (EV, FC, MCU Versions) Page 28 of 28...

Table of Contents