3.
Principle of operation
3.1
Touch Panel
The OMD-2008 Series Touch Display consists of several buttons and LEDs. Each button/
LED has its own specific function.
+
A.
button
B.
OK button
AL1/2 button/
C.
LED
D.
SYS button/ LED
E.
SET button
F.
Arrow Slider
G.
LOG button
H.
TEST button
I.
ON button/ LED
-
J.
button
K.
ESC button
Display
L.
3.2
Measuring Principle
An optical sensor array measures a combination of light scattered and absorbed by oil
droplets in the sample stream. The sensor signals are processed by a microprocessor to
produce linearized output.
If an alarm (set point form 1 ppm to 15 ppm) occurs, the two oil alarm relays are activated
after the adjusted time delay.
The microprocessor continuously monitors the condition of the sensor components and
associated electronics to ensure that calibration accuracy is maintained over time and
extremes of environmental conditions.
3.3
Display Visualization
The display visualizes the oil content status of the units. Using the buttons, it is also
possible to see information about the settings.
Figure 1 Touch Panel
Page: 11 of 102
OMD-2008