Specification Omd-2008 Ev - Deckma Hamburg OMD-2008 Series Instruction Manual

15ppm bilge alarm
Hide thumbs Also See for OMD-2008 Series:
Table of Contents

Advertisement

5.1

Specification OMD-2008 EV

Range:
Accuracy:
Linearity:
Display:
Power Supply:
Consumption:
Alarm Points 1 + 2:
Alarm 1 Operating Delay:
(for annunciation purpose)
Alarm 2 Operating Delay:
(for control purposes)
Alarm Indication:
(Alarm 1, 2, System Fault)
Alarm Contact Rating:
(Alarm 1, 2, System Fault)
Output Signal:
Sample/ Fresh Water pressure:
Sample Flow:
Sample Water Temperature:
Ambient Temperature:
Roll:
Size:
(Computer Unit / Measuring Cell)
Weight: (with Measuring Cell)
Degree of Protection:
Pipe connections:
 Technical specifications are subject to change without notification.
*By request the alarm set point can be set to 5 ppm max.
0 – 30 ppm, Trend indication 50 ppm
According IMO MEPC. 107(49)
0 – 30 ppm better than ± 2 %
Yellow Graphic Display
24 V – 240 V AC or DC
Automatic Voltage selection
< 10 VA
Adjustable between 1 – 15 ppm*
(Works adjustment 15 ppm)
Adjustable between 1 – 540 sec.
(Works adjustment 2 sec.)
Adjustable between 1 – 10 sec.
(Works adjustment 10 sec.)
Red LEDs
Potential free 1 pole change over contacts,
3 A / 240 V
0 – 20 mA or 4 – 20 mA selectable, active,

ext. Load < 150
0 – 6 bar recommended range of installation
Approx. 2 l/min
+1 to +65 °C
+1 to +55 °C
Up to 45°
360 mm W x 240 mm H x 120 mm D
6 kg
IP 65
R ¼" Female
Page: 23 of 102
*