Selection Example Of Wires - Mitsubishi Electric MELSERVO-J4 Instruction Manual

General-purpose ac servo servo amplifier
Hide thumbs Also See for MELSERVO-J4:
Table of Contents

Advertisement

9. OPTIONS AND PERIPHERAL EQUIPMENT

9.6 Selection example of wires

The following diagram shows the wires used for wiring. Use the wires given in this section or equivalent.
2) Control circuit power supply lead
5) Power regenerative converter lead
Power regenerative converter
POINT
To comply with the UL/CSA standard, use the wires shown in appendix 1 for
wiring. To comply with other standards, use a wire that is complied with each
standard.
Selection conditions of wire size is as follows.
Construction condition: One wire is constructed in the air.
Wire length: 30 m or less
Power supply
Regenerative option
3) Regenerative option lead
1) Main circuit power supply lead
Servo amplifier
L1
L2
L3
L11
L21
N-
C
P+
9 - 39
U
V
W
4) Servo motor power lead
M

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j4-a4Mr-j4-a4-rjMr-j4b4Mr-j4b4-rj

Table of Contents