9. OPTIONS AND PERIPHERAL EQUIPMENT
When using the FR-CV-H, always install the dedicated stand-alone reactor (FR-CVL-H).
(3) Connection diagram
(a) For MR-J4-_A4(-RJ)
(Note 7)
MCCB
3-phase
380 V AC
to
480 V AC
Step-down
transformer
Note 1. Configure a sequence that will shut off main circuit power in the following.
An alarm occurred at FR-CV-H or servo amplifier.
EM1 (Forced stop 1) is enabled.
2. For the servo amplifier, configure a sequence that will switch the servo-on after the FR-CV-H is ready.
3. For the FR-CV-H, the RSO signal turns off when it is put in a ready-to-operate status where the reset signal is input. Configure
a sequence that will make the servo inoperative when the RSO signal is on.
4. Configure a sequence that will make a stop with the forced stop input of the servo amplifier if an alarm occurs in the FR-CV-H.
5. When using FR-CV-H, always disconnect wiring between P3 and P4 terminals.
6. Set [Pr. PA04] to "0 0 _ _" to enable EM1 (Forced stop 1).
7. When wires used for L11 and L21 are thinner than wires used for L1, L2, and L3, use a molded-case circuit breaker.
8. The illustration of the 24 V DC power supply is divided between input signal and output signal for convinence. However, they
can be configured by one.
Power regenerative common
converter
FR-CV-H22K(-AT)
FR-CV-H30K(-AT)
FR-CV-H37K
FR-CV-H55K
POINT
In this configuration, only the STO function is supported. The forced stop
deceleration function is not available.
FR-CVL-H
MC
R/L11
R2/L12
S/L21
S2/L22
T/L31
T2/L32
RESET
(Note 1)
RA1
RA2 EM1 OFF
ON
MC
MC
SK
Dedicated stand-alone
reactor
FR-CVL-H22K
FR-CVL-H30K
FR-CVL-H37K
FR-CVL-H55K
FR-CV-H
R2/L1
S2/L2
T2/L3
P/L+
N/L-
24 V DC
R/L11
S/L21
P24
T/MC1
SD
RES
RDYB
(Note 2)
RA3
SD
RDYA
A
(Note 1)
RA1
B
(Note 2)
RA3
C
RA1 (Note 4)
(Note 3)
RSO
SE
24 V DC (Note 8)
9 - 35
Servo amplifier
U
L11
V
L21
W
CN2
P4
(Note 5)
N-
24 V DC (Note 8)
DOCOM
ALM
SON
SON
EM1
EM1 (Note 1, 6)
RES
DICOM
Servo motor
U
V
W
(Note 1)
RA2