9. OPTIONS AND PERIPHERAL EQUIPMENT
9.9 Power factor improving AC reactor
The following shows the advantages of using power factor improving AC reactor.
It improves the power factor by increasing the form factor of the servo amplifier's input current.
It decreases the power supply capacity.
The input power factor is improved to about 80%.
When using power factor improving reactors for two servo amplifiers or more, be sure to connect a power
factor improving reactor to each servo amplifier. If using only one power factor improving reactor, enough
improvement effect of phase factor cannot be obtained unless all servo amplifiers are operated.
W1
W ± 0.5
150
125
W1
W ± 0.5
Note. Use this for grounding.
4-d mounting hole (Note)
(φ5 groove)
R X
S Y T
Z
D or less
D2
D1
Fig. 9.4
R X S
Y T
Z
4-d mounting hole (Note)
(φ6 groove)
D or less
D2
D1
Fig. 9.5
3-phase
380 V AC to
480 V AC
180
W1
W ± 0.5
9 - 44
Servo amplifier
FR-HAL-H
MCCB
MC
R
X
S
Y
T
Z
R X S
Y T
4-d mounting hole (Note)
(φ8 groove)
D or less
D2
D1
Fig. 9.6
3-phase
400 V class
L1
L2
L3
Z