The following table gives the 1st level functions and the adjustable parameters.
�=DEFAULT value set in factory.
Par
Selects the functioning logic.
Lo
(see notes after the table)
r,
Close input configuration (see
LL
notes after the table)
Fe
Photocells
Ob
Obstacle detection
(for hydraulic bollards only)
PO
Opening-warning time
P [
Closing-warning time
Ld
Bollard lights
cP
Pause time (in seconds)
bU
Buzzer
Preset controlling entrance
Pr
configuration
Resetting default parameters.
dF
(see notes after the table)
Sc
Exiting the menu/saving
Description of level 1 parameters
, lo: F unctioning logic
- Hold-to-run: Close function active for as long as inputs are active. Open function activated by activating and releasing input. The
start command opens once and closes once.
- Semi automatic: The automation works with jog commands, without automatic reclosing. Hence, when fully open, to control closing
you need to act on the start or close command respectively.
- Automatic: The automation works in jogs. When the opening manoeuvre is completed in the standard cycle, automatic reclosing is
activated after the pause time set (parameter 1::P).
www.BFTGateOpeners.com | (800) 878-7829 | Sales@BFTGateOpeners.com
•ijuJ13i
8.2
Function
00: Hold-to-run
0 I: Semi automatic
02: Automatic
00: Standard close input
0 I: Close-when-released input
02: The close command acts as a close-when-released and safety function.
00: During, it reopens and waits for the photo cell free commands closing.
0 I: When closing it reopens; closes after 1 "when the photocell is free
02: When closing it reopens; closes after 5" when the photocell is free
00: Disabled
0 I: When closing it stops and waits for commands
02: When closing it reopens and waits for commands
03: When closing it reopens, then closes after 5 seconds
0-30
0-30
00: Cover lights flashing during movement, fixed on when the bollard is
opened and closed
0 I: Cover lights flashing during movement and with bollard open, fixed on
when the bollard is closed
02: Cover lights always flashing
03: Cover lights flashing during movement and with bollard closed, fixed
on when the bollard is open
00-99
00: Buzzer off
0 I: Buzzer on during movement
0 I: none
02: Configuration of installation type A parameter (see chapter 13.1)
03: Configuration of installation type B parameter (see chapter 13.2)
01./: Configuration of installation type C parameter (see chapter 13.3)
05: Configuration of installation type D parameter (see chapter 13.4)
00: No resetting
0 I: Resetting the default parameters
02: Same as O I, except for"COM" parameters that are not reset
Pressing the "F" key exits the programming menu and changes are saved
ti\=
Control unit
PROGRAMMING
parameter value set during installation: should be filled if
DEFAULT value is modified.
Settable data
- 30 -
ti\
01
00
02
03
00
00
00
10
01
01
00