14. ERROR HANDLING

The control board can store up to 10 different errors, with no. of occurrences limited to 10, for each event.
In case of blocking (severe) error, it is possible to restart the board by pressing both keys"+" and"-" for 5 seconds or by switching off
and on the power supply. When restarting by means of keys, a memory check is performed and automatic recovery of out-of-range
parameters is done. The parameters are set to default factory values, so a new setup should be done, if necessary.
In level 4 menu, parameter "Err'; shows the list of events and error stored in memory. The display shows alternatively the error code
Exx
and the number of occurrences. Use "+" e"-" for scroll the whole list.
At the end of the list, an exit code is presented: quitting (by pressing "F") with
error history is cleared to zero.
Events/warning not severe are stored in memory, without blocking the normal behaviour of the control board.
List of errors and events with the indication of blocking/not blocking:
FAULT AND EVENTS TABLE:
Par
EID
Internal error on memory access.
E IY
Out of range memory address.
E20
Fuse F2 or F3 blown or not present.
Ee I
STOP occurred, changing the normal automation behaviour.(*)
E23
Obstacle detected during operation.
E2Y
Time-out elapsed while opening.
E25
Time- out elapsed while closing.
E21
Break on U- Link communication.
E2B
Programmed maintenance cycles reached.
E29
Close limit switch not working (when present and enabled).
E92
MODBUS: unknown command.
E95
MODBUS: parity parameter error. Internal error.
E91
MODBUS: wrong parameter or data length.
E99
Communication parameter unknown
(*) Events occurrence that change the normal behaviour, such as STOP, obstacle detection, etc., are stored.
For example, if STOP input activates during a static status (automation stopped), the event is not saved; but if it prevents a movement
or inhibits a command, it is stored.
www.BFTGateOpeners.com | (800) 878-7829 | Sales@BFTGateOpeners.com
Control unit
000
the error list is preserved, quitting with
Description
- 41-
m
00
I the
BLOCKING
YES
YES
YES
NO
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES