Cn (Exit Command Mode); Ac (Apply Changes); Gt (Guard Times) - Digi XBee User Manual

S1 802.15.4 (legacy) rf modules
Hide thumbs Also See for XBee:
Table of Contents

Advertisement

AT commands
Parameter range
2 - 0xFFFF (x 100 ms)
Default
0x64 (10 seconds)

CN (Exit Command mode)

Immediately exits Command Mode and applies pending changes.
Parameter range
N/A
Default
N/A

AC (Apply Changes)

Apply changes to queued parameter values and re-initialize the device.
Applying changes means that the device is re-initialized based on changes made to its parameter
values. Once changes are applied, the device immediately operates according to the new parameter
values.
This behavior is in contrast to issuing the WR (Write) command. The WR command saves parameter
values to non-volatile memory, but the device still operates according to previously saved values until
the device is rebooted or the CN (Exit Command Mode) is issued. For more information, see
Command - Queue Parameter Value frame -
Note
Minimum firmware version required: 1.xA0. Firmware versions are numbered in hexadecimal
notation.
Parameter range
N/A
Default
N/A

GT (Guard Times)

Set the required period of silence before and after the command sequence characters of the
Command mode sequence (GT + CC + GT). The period of silence prevents inadvertently entering
Command mode.
See
Command mode options
Parameter range
0x2 - 0xCE4 (x 1 ms)
Default
0x3E8 (one second)
XBee/XBee-PRO S1 802.15.4 (Legacy) User Guide
0x09.
for more information about AT Command mode.
Command mode options
AT
84

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xbee-pro

Table of Contents