AT commands
CN (Exit Command mode)
Executable command. This command immediately exits Command mode and applies pending changes.
Parameter range
N/A
Default
N/A
CT (Command Mode Timeout)
Sets or displays the Command mode timeout parameter. If a device does not receive any valid
commands within this time period, it returns to Idle mode from Command mode.
Parameter range
2 - 0x1770 (x 100 ms)
Default
0x64 (10 seconds)
GT (Guard Times)
Set the required period of silence before and after the command sequence characters of the
Command mode sequence, GT + CC + GT (including spaces). The period of silence prevents
inadvertently entering Command mode. For more information, see
Parameter range
0x2 - 0x6D3 (x 1 ms)
Default
0x3E8 (one second)
CC (Command Character)
The character value the device uses to enter Command mode.
The default value (0x2B) is the ASCII code for the plus (+) character. You must enter it three times
within the guard time to enter Command mode. To enter Command mode, there is also a required
period of silence before and after the command sequence characters of the Command mode
sequence (GT + CC + GT). The period of silence prevents inadvertently entering Command mode. For
more information, see
Parameter range
0 - 0xFF
Default
0x2B (the ASCII plus character: +)
Sleep settings
The following AT commands are sleep commands.
XBee3® 802.15.4 RF Module User Guide
Enter Command
mode.
Sleep settings
Enter Command
mode.
47