3. Installation
3.1 Prerequisites for the Area of application
38
 
If no forced ventilation is being used, the device must not be mounted at an angle ⍺
l
of more than ±α ≦ 45°.
An inclination angle ⍺greater than 10° is only permissible for certain XV-303-15-...
device models and only at a reduced max. ambient temperature of 45 °C.
For XV-303-15-CE.-..., XV-303-15-C02-.., the inclination angle l ⍺ is limited to α ≦ ±10°
in general.
 
The enclosure material must be thick enough
l
XV-303-10-.., XV-303-70-..
for front mounting 2 mm (0.08") ≦ d ≦ 5 mm (0.2"),
XV-313-10-.., XV-313-70-..
for rear (panel) mounting XV-313-..-...-A00-..d = 1.5 mm (0.059") ± 0.1mm (0.004"),
XV-313-..-...-A11-.. d = 2 mm (0.08") ± 0.1mm (0.004")
XV-303-15-..
for front mounting 1.5 mm (0.06") ≦ d ≦ 4 mm (0.16")
as well as flatness
→ DIN ISO 2768-2 (K)
 
Recommended mounting cutout
l
for front mounting
XV-303-70-..:e = 183 mm (7.20") ± 1 mm (0.04"), f = 122 mm (4.80") ± 1 mm (0.04")
XV-303-10-..: e = 255.5 mm (10.06") ± 1 mm (0.04"), f = 160.5 mm (6.32") ± 1 mm
(0.04"),
XV-303-15-..:e = 388 mm (1x6") ± 0.5 mm (0.02"), f = 239 mm (x2") ± 0,5 mm (0.02")
for rear (panel) mounting
XV-313-70-..: e = 182.7 mm (7.193") ± 0.1 mm (0.004"), f = 126.8 mm (4.992") ± 0.1 mm
(0.004")
XV-313-10-..: e = 255.7 mm (10.07") ± 0.1 mm (0.004"), f = 165.8 mm (6.528") ± 0.1 mm
(0.004")

Figure 16: Mounting position

XV300  04/19 MN048017EN  www.eaton.eu
≦ 0.5 mm (0.02") am Einbauausschnitt bei
α
α
Rz ≦ 120; IP 65
e