Marine Approvals - Eaton XV300 Manual

Hide thumbs Also See for XV300:
Table of Contents

Advertisement

1. Description

1.11 Marine approvals

1.11 Marine approvals
26
Obtained type approvals
XV300 multi touch display 7.0" and 10.1" have been granted the required by Det Norsk
Veritas / Germanischer Lloyd (DNV GL)
 
DNVGL-CG-0339 type approval, November 2015 edition,
l
"Environmental test specification for electrical, electronic and programmable equip-
ment and systems"
Certificate No.: TAA00000NC
Location classes
temperature B - Ambient temperature: 0°C to +55°C
Humidity
B - Relative humidity up to 100 % at all relevant temperatures.
Vibration
A - Bulkheads, beams, deck, bridge, acceleration amplitude: 0.7 g
emc
A* - All locations except bridge and open deck
B* - All locations (including bridge and open deck)
Input
Required protection according to DNV-GL Rules shall be provided upon installation on board
* Filters / Ferrites maybe required to fulfil. See installation restrictions
Installation restrictions
 1. Install and commission referring to manuals.
 2. Screened communication cables improve EMC behavior
 3. PE connection of communication cables improve EMC behavior (e.g. earth-con-
nection kit: EATON ZB4-102-KS1)
Location class
interface
EMC B
Power supply
EMC A
 
Please refer to the following as well → Section "Conditions for Marine approvals",
page 40
XV300  04/19 MN048017EN  www.eaton.eu
Installation
Place interference filter
No additional installations

Advertisement

Table of Contents
loading