Eaton XAP Series Instruction Booklet

Eaton XAP Series Instruction Booklet

Busduct storage

Advertisement

Quick Links

Instruction Booklet IB
XAP Series Busduct
Storage, Installation, and Maintenance
Joint cover
XAP Series Busduct
Contents
Description
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Receiving . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Unloading and Handling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Preparation and Inspection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Identification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Joint Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Joint Cover Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Expansion Joint Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
End Cover Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Settlement Joint Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Horizontal Mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Vertical Mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wall Penetrations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Busduct Joint Clearances. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tap-off Unit Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Attentions for Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Construction after Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Steps for Energizing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maintenance Procedures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tap-off Unit Inspection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Note. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Effective January 2017
XAP Series Busduct
Tap-off Units
Page
1
1
1
1
1
2
2
2
3
3
3
3
4
4
4
5
5
6
6
6
6
7
7

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XAP Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Eaton XAP Series

  • Page 1: Table Of Contents

    Instruction Booklet IB Effective January 2017 XAP Series Busduct Storage, Installation, and Maintenance Joint cover XAP Series Busduct XAP Series Busduct Tap-off Units Contents Description Page Introduction............. . .
  • Page 2: Introduction

    Inspect the XAP busduct joints to ensure they are clean and that the insulators The Eaton XAP busduct should be stored in a covered, clean, dry space are not cracked or broken.
  • Page 3: Installation

    "N" label in alignment. Figure 3 illustrates correct joint installation. Identification Each piece of the Eaton XAP busduct has a nameplate label as shown in Figure 1. This label identifies each piece and its ratings. It is recommend- ed that each piece be installed sequentially, starting at the beginning point of the run.
  • Page 4: Joint Cover Installation

    Instruction Booklet IB XAP Series Busduct Storage, Installation, and Maintenance Effective January 2017 Joint Cover Installation End Cover Installation After the connectors are tightened, the joint covers may be installed in End Cover is the end of a busduct system. It is composed of insulating turn and tightened with bolts.
  • Page 5: Horizontal Mounting

    Wall Penetrations For over-head mounting of the Eaton XAP busduct, all-thread drop rods When an Eaton XAP busduct passes through a wall or vertical barrier, must be provided by the installer and should not be spaced more than the opening should be at least 100 mm larger than the outside 2m apart.
  • Page 6: Busduct Joint Clearances

    Instruction Booklet IB XAP Series Busduct Storage, Installation, and Maintenance Effective January 2017 Busduct Joint Clearances Tap-off Unit Installation Busduct joint sections may not fall within walls or floors. Figures 13 Phase sequence shall be made according to field application require- through 15 illustrate the minimum clearances required as measured ments and construction drawings.
  • Page 7: Attentions For Installation

    DAMAGE, SERIOUS PERSONAL INJURY AND DEATH. A preventative maintenance schedule should be established in order to achieve the best possible service from your Eaton XAP busduct. 1. After the busduct has been de-energized, remove the joint covers and visually inspect the joints looking for gaps in the contact surface It is recommended that an annual maintenance check and necessary areas, cracks in the insulators, and contaminants or corrosion;...
  • Page 8: Tap-Off Unit Inspection

    Specific applications may require additional steps and procedures. For additional information or assistance with issues not covered sufficiently in this publication, contact the local Eaton sales office. EATON CORPORATION www.eaton.com.cn/electrical...
  • Page 9 Eaton is a power management company with 2016 sales of $19.7 billion. We provide energy-efficient solutions that help our customers effectively manage electrical, hydraulic and mechani- cal power more efficiently, safely and sustainably. Eaton is dedicated to improving the quality of life and the environment through the use of power management technologies and services.

This manual is also suitable for:

Xap-cXap-a

Table of Contents