Fig. 104: Dismantling the module fan
Fig. 105: Remove the module fan incl. cable
and rubber sealing
19

Spare parts

Installation and operating instructions Wilo-Yonos GIGA2.0-I/-D
Spare parts
3.
Loosen the screws of the module fan.
4.
Remove the module fan and loosen the cable with rubber sealing from the module
lower part.
Installing the module fan
Install the module fan in reverse order.
Obtain genuine spare parts only from a qualified specialist or Wilo customer service. To
avoid queries and order errors, please provide all pump and drive rating plate data with
every order. Pump rating plate see Fig. 2, Item 1, drive rating plate see Fig. 2, Item 2.
CAUTION
Risk of material damage!
Trouble-free pump operation can only be guaranteed when original spare parts are
used.
Use only original Wilo spare parts!
Information to be provided when ordering spare parts: spare part numbers, spare
part names/descriptions, all data from the pump and rating plate. This helps prevent
return queries and incorrect orders.
NOTICE
For a list of genuine spare parts, see the Wilo spare parts documentation
(www.wilo.com). The item numbers of the exploded view drawing (Fig. I and Fig. II)
are for orientation and listing of pump components.
These item numbers are not to be used for spare parts orders!