Low Water Level in the Tank.
The water tank failed to fill completely within the prescribed time. The water inlet valve is
deactivated for safety reasons.
- Maximum filling time is four (4) minutes when the power switch of the coffee brewer has been set
to the ON position.
- Maximum filling time is two (2) minutes after the first tank fill.
Check water supply line to ensure that the pressure is adequate (between 20 and 80 PSI). If the
machine uses a waterline filter, it might be worn out and needs to be replaced.
Press on the "Restart Filling" button on the error screen to restart the tank filling process.
Water Tank Not Full. Please Wait While Filling (1 to 3 minutes).
After setting the power switch of the machine to the ON position, this message will be displayed
until the water tank is full.
Water Temperature Not High Enough. Please Wait.
The machine will display this message and stop dispensing drinks if the water temperature of the
tank drops below the "Min. Water Temp(F)" temperature set in Service mode (see section 6.6.1). To
disable this feature, set the warming up temperature to 0.