Iat Sensor Removal - Mercury V6 175 Diagnostic Manual

Table of Contents

Advertisement

Sensors
4.
Perform a continuity check of the sensor wiring between the sensor connector and the PCM. Note that there are splices in
the sensor ground circuit.
NOTE: The quickest way to check the wiring is to measure the resistance of the thermistor at room temperature, connect
the sensor to the engine harness, and measure the resistance across PCM connector sockets CE1 and BL2. If the two
resistance values match, then the wiring is good.
DMT 2004 Digital Multimeter
Terminal Test Probe Kit
M
b
A
4
1
A
c
H
1
4
Connector
A
B
65666

IAT Sensor Removal

1.
Remove the starboard air intake runner. Refer to the appropriate service manual.
2.
Disconnect the engine harness connector from the IAT sensor.
Page 5A-24
Intake Manifold Air Temperature Sensor Resistance Test
Temperature
0 °C (32 °F)
15 °C (59 °F)
25 °C (77 °F)
100 °C (212 °F)
A1
TAN
L2
100A
M4
A1
E1
BLK/ORN
100B
H4
Pin
Wire Color
A
Tan
B
Black/orange
© 2018 Mercury Marine
91‑892647A01
Bosch P/N MM‑ 46523
TAN
A
BLK/ORN
B
67519
Air temperature signal
Sensor ground A (–)
Reading
6.18–6.83 kΩ
3.04–3.36 kΩ
2.00–2.21 kΩ
0.14–0.16 kΩ
a -
Intake air temperature (IAT)
sensor connector
a
b -
PCM connector B
c -
PCM connector C
Function
90-8M0146617 eng JULY 2018
PCM
BL2
CE1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

V6 200V6 225V8 200V8 225V8 250V8 300

Table of Contents