Fault Codes
•
Restricted sensor reference hose
•
Valve train issue
Summary of Fault Correction Possibilities
•
Replace the sensor.
•
Correct the wiring problem.
•
Check the reference hose for leaks.
•
Check the cylinder leak down.
MAP_Time_RangeLow
Fault Type:
Horn:
Nonsticky
Caution
Explanation
The manifold absolute pressure (MAP) sensor does not appear to be working properly; the PCM received a signal that is below
the valid limit.
Possible Causes
•
Sensor out of range
•
Wiring problem
•
Restricted sensor reference hose
•
Valve train issue
Summary of Fault Correction Possibilities
•
Replace the sensor.
•
Correct the wiring problem.
•
Check the reference hose for leaks.
•
Check the cylinder leak down.
MAPR_TPS1Rationality
Fault Type:
Horn:
Nonsticky
Caution
Explanation
The values received from the manifold absolute pressure (MAP) sensor and the primary encoder in the throttle position sensor
(TPS) do not agree.
Possible Causes
•
MAP or ETC wiring problem
•
ETC opening is restricted or airflow to the engine is restricted
•
Intake manifold has vacuum leak
•
MAP sensor or ETC is failed
Summary of Fault Correction Possibilities
•
Correct the MAP sensor or ETC wiring problem.
•
Inspect the cold air intake assembly for obstructions.
•
Inspect the intake manifold for air leaks.
•
Replace the MAP sensor or throttle body assembly.
Page 4A-26
Guardian:
UFC:
100%
401‑25
Guardian:
UFC:
100%
404‑6
© 2018 Mercury Marine
Transmission to Helm:
Yes
Transmission to Helm:
Yes
Freeze Frame Priority:
2
Freeze Frame Priority:
2
90-8M0146617 eng JULY 2018