Faulty terminator resistor
Summary of Fault Correction Possibilities
Correct the wiring problem.
Install the correct count of resistors.
Replace the faulty resistor.

Dual_DemandSen_Fault

Fault Type:
Horn:
Nonsticky
Critical
Explanation
The throttle demand sensor does not appear to be working properly.
Possible Causes
Wiring problem
Defective sensor
Summary of Fault Correction Possibilities
Repair the wiring.
Replace the sensor.

Dual_ShiftDemandSen_Fault

Fault Type:
Horn:
Sticky
Critical
Explanation
The shift demand sensor does not appear to be working properly.
Possible Causes
Wiring problem
Defective sensor
Summary of Fault Correction Possibilities
Repair the wiring.
Replace the sensor.

Dual_ShiftPosSen_Fault

Fault Type:
Horn:
Nonsticky
Critical
Explanation
The shift position sensors do not appear to be working properly.
Possible Causes
Shift actuator wiring problem
Failed shift actuator
Summary of Fault Correction Possibilities
Inspect the wiring to the shift actuator.
Replace the shift actuator.
90-8M0146617 eng JULY 2018
Guardian:
UFC:
5%
1074‑6
Guardian:
UFC:
5%
1078‑6
Guardian:
UFC:
100%
1025‑6
Transmission to Helm:
Yes
Transmission to Helm:
Yes
Transmission to Helm:
Yes
© 2018 Mercury Marine
Fault Codes
Freeze Frame Priority:
4
Freeze Frame Priority:
4
Freeze Frame Priority:
4
Page 4A-13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

V6 200V6 225V8 200V8 225V8 250V8 300

Table of Contents